Glass buildings pose immense dangers to birds. In the United States alone, up to 2 billion birds are killed yearly due to collisions with glass, based on data from the U.S. Geological Survey’s Bird Banding Laboratory. According to a paper, “Bird–Building Collisions in the United States: Estimates of Annual Mortality and Species Vulnerability,” 56% of birds die in collisions with low-rise buildings, emphasizing the need to install bird-friendly glazing in the first 100 feet above grade.

The glass industry’s push to reduce bird collisions includes the addition of “Addendum o” in ASHRAE 189.1 and the International Green Construction Code. The addendum was approved by ASHRAE and the American National Standards Institute on Jan. 30, 2026. It introduces a new bird-friendly design requirement for building facades to promote uniformity around glazing requirements. It is written as a jurisdictional option to fit a region’s particular environment.

“Research on bird-friendly glazing for collision prevention has guided the development of bird-friendly building design,” reads the addendum’s forward. “Creating visual markers on the glass at a specific spacing and geometry to interrupt reflections and transparency has been shown to significantly reduce bird collisions. This addendum specifies requirements for the location and characteristics of this type of glass.”

In the United States alone, up to 2 billion birds are killed yearly due to collisions with glass. Photo: Alexander Image/Shutterstock.

Key Requirements and Exemptions

The addendum’s language applies to vertical windows, spandrel glass, skylights, corner glazing and glazed railings in areas up to 100 feet above grade in new buildings and major alterations. According to Section 5.3.7 of Addendum o, bird-friendly glass should be installed in a new vertical fenestration area that is being replaced during existing building renovations. Bird-friendly glass may be installed in locations:

  • Not less than 90% of the area of vertical fenestration, glass spandrel and skylights below 100 feet above grade;
  • For existing buildings, not less than 90% of the area of vertical fenestration being replaced below 100 feet above grade;
  • Not less than 90% of the area of vertical fenestration, glass spandrel and skylights adjacent to and within the first three stories above roof areas with vegetation or water features; and
  • Where glazed, all glazed corners, fly-through conditions, glazing adjacent to courtyards, skywalks, building connectors, railings, noise barriers and wind barriers below 100 feet above grade.

Furthermore, the first or second surface of the bird-friendly glazing should have opaque, translucent or ultraviolet reflective visual markers not smaller than 1/8 inch, not more than 2 inches between linear continuous visual markers and a density pattern such that a circle with a diameter no more than 2.7 inches will fit between discrete point visual markers. The glazing should also have a bird-friendly configuration, including opaque, etched and ultraviolet reflective markers approved by the jurisdiction.

Several exemptions to the above section include places of religious worship and buildings on the National Register of Historic Places.