What Bigger Unitized Panels Mean for Design and Installation
A 44-foot-tall, unitized curtainwall panel hanging from a crane does not just change how a building goes together; it changes how teams think about design, logistics and risk. Unitized systems are pre-assembled and fabricated in a factory before onsite installation, enabling improved assembly and sealing in a controlled environment over stick-built curtainwalls.
Gijs Libourel, principal and senior specialist, façade, at Vancouver-based RDH Building Science Inc., says that overall, unitized systems offer a bevy of advantages, most notably the benefit of more work in the shop rather than in the field, enhancing quality control and offering a more predictable installation process.
As these systems scale up to meet architectural ambition and energy performance targets, even small changes in size or weight can ripple through engineering, fabrication and installation decisions.
Weight, Size, Performance
It’s reasonable to assume that, with building energy codes becoming more stringent and more widely adopted, and as demand for larger panels increases, unitized curtainwall systems are becoming heavier as a result.
Libourel notes that while there are certainly projects where unitized panels have grown in size, sometimes up to double typical dimensions, overall, the size and weight of these panels have not changed fundamentally. At the same time, as Chris Vogler, general superintendent of New York-based Ajay Glass Company, points out, the push for larger glass panels means:
- Thicker glass is needed to meet engineering requirements;
- An increase in the span between anchors, which can then lead to thicker aluminum extrusions and/or;
- Added steel reinforcement in the verticals.
Each of these factors can increase the weight of unitized curtainwall systems incrementally.
Meanwhile, stricter energy codes are encouraging design teams to explore alternatives to traditional aluminum-and-glass systems. Libourel explains that interest has grown in mixed-material assemblies, hybrid systems and panelized enclosures that balance energy performance, carbon considerations, durability and constructability.
Granted, national model energy codes, such as the International Energy Conservation Code and ASHRAE 90.1, don’t specifically require thicker glass, but they do push for higher thermal performance. This can influence the glass assemblies specified, which sometimes results in thicker units or more complex glazing, adding weight to the curtainwall system. However, the Department of Energy and the National Fenestration Rating Council note that low-E coatings, warm-edge spacers and improved framing often contribute more to better U-values than raw glass thickness.
With unitized panels growing larger and assemblies becoming more complex, evaluating performance at the joints, rather than just at the center of glass, is critical. That’s because a unitized curtainwall isn’t one continuous assembly; it’s multiple factory-built panels tied together onsite. To ensure these systems meet performance requirements, thermal modeling has become more pertinent, says Vogler.
“… We are seeing a lot of discussion around thermal performance on the ‘big’ projects and are lucky to have our own thermal engineer on our staff,” he explains. “It’s eye-opening when you see how surrounding conditions can affect your curtainwall performance. We have had to design special backpans on projects to allow the interior air to ‘surround’ the vertical to meet specs on some projects. It’s not a ‘one-size-fits-all’ business anymore.”
As designers explore ways to meet stricter codes and overcome increasingly complex challenges without adding excessive weight, hybrid systems have emerged as a compelling solution.
Curtainwood
Libourel has noticed the emergence of hybrid façade systems that combine curtainwall installation methods with alternative structural materials, allowing larger prefabricated façade units with the performance and onsite efficiency of traditional unitized curtainwalls. This enables builders to install bigger sections faster while keeping the same performance as traditional curtainwalls.
“One of the most interesting developments is the hybridization of façade system design,” explains Libourel. “A good example is what we refer to as ‘CurtainWood,’ where a cross-laminated timber panel provides the structural backbone of the façade. The weather barrier, insulation, cladding and glazed openings are all shop-applied, allowing the assembly to be installed onsite much like a unitized curtainwall, with stack joints and drained, pressure-moderated design principles rather than the monolithic approach of precast concrete. These hybrid systems enable much larger façade units while preserving the installation logic and performance expectations of curtainwall technology.”
Hybrid curtainwall systems combine different materials and technologies, such as glass with metal, wood or composite panels, or integrate aspects of stick-built and unitized systems, to achieve:
- Improved thermal performance;
- Easier installation; and
- Greater design flexibility than traditional systems.
These systems offer a versatile, high-performance solution that addresses the limitations of conventional curtainwall and window wall systems, focusing on thermal performance, design flexibility and ease of installation.
Nevertheless, as unitized units increase in size and incorporate nontraditional materials, questions naturally arise about how those changes affect tolerances, movement and long-term performance.
Installation, Logistics, Safety
Libourel says that heavier unitized systems mostly affect the hardware and anchorage design. He explains that tolerances and movement accommodation scale with the size and orientation of the units, so larger panels require more careful detailing of stack joints, vertical drift allowances and perimeter clearances.
“Weight doesn’t directly affect tolerances, but it often drives the need for more robust support structures,” adds Vogler. “The bigger units affect caulk joint sizes. Forty-four-foot-tall units cannot have ½-inch caulk joints due to thermal movements. We recently completed a bridge expansion at the Albany International Airport, which had 44-foot-tall, unitized curtainwall frames, and it was pretty wild.”
Vogler says that setting units that weighed more than 5,000 pounds for the Albany project was a noteworthy experience.
“We used a Woods Powr-Grip cup manipulator, which would tilt the unit to plumb it or rotate it,” he explains. “It worked like a charm, but that unit weighed 10,000 pounds, so when the crane tells you there’s $15K on the hook, you need a whole new respect for safety. The bigger unitized curtainwalls are engineered to perform just as well as the old days of 14-foot units, but when you get done, there’s something way more impressive about 44-foot-tall units.”
As Vogler mentions, the increased size of unitized systems adds a new dimension to logistics and installation.
“Larger units can accelerate enclosure and dry-in, which installers appreciate, but they also consume valuable crane time, which general contractors carefully manage,” explains Libourel. “As a result, heavier units tend to be more common on low- and mid-rise projects, while high-rise construction still favors unitized systems that can be installed from the floor without relying on tower crane resources.”
Weight becomes a factor when panels can no longer be installed from the interior with a floor-mounted crane or a spider crane. Libourel notes that once installation requires a tower crane, mobile crane or significant use of a boom lift, site logistics change dramatically, and the discussion around feasibility and sequencing shifts as well. To improve the installation process, lifting points are engineered to accommodate large units.
Vogler says that even for small projects, “winging it” should be a thing of the past. Overhead cranes in the shop, power cups for setting glass during glazing and other lifting devices are becoming standard practice, and that is a good thing, he notes.
“Using machines not only improves safety but also protects our bodies long term, which matters even more given the lack of young workers entering the trades,” he says.
Ultimately, the evolution of unitized curtainwalls is less about sheer size or weight than it is about balance. As panels grow larger and performance expectations rise, design teams are asked to reconcile energy codes, constructability, logistics and long-term durability. Unitized systems continue to offer speed and consistency, but achieving those benefits now requires earlier collaboration, deeper analysis and a willingness to look beyond conventional aluminum-and-glass solutions.
Tolerance, Tools and Teamwork: Keys to Installing Large Unitized Panels
As unitized curtainwall panels grow in size and complexity, even small increases in weight can ripple through design and installation, making early planning and precise layout critical from day one, says Chris Vogler of Ajay Glass Company.
“The beauty of unitized curtainwall is that there’s usually tolerance in the anchors to accommodate building tolerances,” he explains. “The difficulty is getting other trades to understand that +/-1 inch means you can’t be 2 inches out of plumb. They all seem to think the tolerance keeps resetting every 10, 20 or 50 feet.”
Here is a peek at how Vogler says experienced teams keep projects on track:
- Design Assist vs. Architect Prep: On projects where the architect has done the homework and the structure can handle the “loads imposed” by the curtainwalls, things flow smoothly. On smaller or less-engineered projects, critical details can be overlooked, especially by newer glazing companies. Experience matters; catching potential issues early prevents headaches later.
- Tolerance is a Friend: Unitized systems allow anchor tolerances to accommodate building movement, but do not assume that tolerance resets every few feet. Accurate layout is everything.
- Surveying Makes the Difference: Having an in-house survey and layout team ensures anchors and panels are placed correctly. With laser scanners and total stations, your team can create as-builts and layout anchors to within ⅛ inch, even on massive jobsites.
Joshua Huff is the senior editor of USGlass magazine. Email him at jhuff@glass.com and connect with him on LinkedIn.
To view the laid-in version of this issue in our digital edition, CLICK HERE.